SignalOffPageConnectorReferenceByNumber

Overview

Class

A reference to a SignalOffPageConnector by drawing and connector number.

Supertypes

Attributes (data)

Name

Multiplicity

Type

ReferencedConnectorNumber

0..1

NullableString

ReferencedDrawingNumber

0..1

NullableString

Implementation in Proteus Schema

The class is implemented as a Proteus XML element with RDL reference.

Tag: <SignalOffPageConnectorReference>

ComponentClass: SignalOffPageConnectorReferenceByNumber

Example

Implementation in Proteus Schema

<SignalOffPageConnectorReference
    ID="signalOffPageConnectorReferenceByNumber1"
    ComponentClass="SignalOffPageConnectorReferenceByNumber"
    ComponentClassURI="http://sandbox.dexpi.org/rdl/SignalOffPageConnectorReferenceByNumber" ...>
  ...
</SignalOffPageConnectorReference>

ReferencedConnectorNumber

Attribute (data)

The connector number of the referenced connector.

Multiplicity: 0..1

Implementation in Proteus Schema

The attribute is implemented as a DEXPI generic attribute for string values.

Name: ReferencedConnectorNumberAssignmentClass

Example

“97” (String)

Implementation in Proteus Schema

<SignalOffPageConnectorReference
    ID="signalOffPageConnectorReferenceByNumber1"
    ComponentClass="SignalOffPageConnectorReferenceByNumber"
    ComponentClassURI="http://sandbox.dexpi.org/rdl/SignalOffPageConnectorReferenceByNumber" ...>
  ...
  <GenericAttributes Set="DexpiAttributes" ...>
    <GenericAttribute
      Name="ReferencedConnectorNumberAssignmentClass"
      AttributeURI="http://sandbox.dexpi.org/rdl/ReferencedConnectorNumberAssignmentClass"
      Format="string"
      Value="97" />
    ...
  </GenericAttributes>
  ...
</SignalOffPageConnectorReference>

ReferencedDrawingNumber

Attribute (data)

The DrawingNumber of the PID that contains the referenced connector.

Multiplicity: 0..1

Implementation in Proteus Schema

The attribute is implemented as a DEXPI generic attribute for string values.

Name: ReferencedDrawingNumberAssignmentClass

Example

“123/A93” (String)

Implementation in Proteus Schema

<SignalOffPageConnectorReference
    ID="signalOffPageConnectorReferenceByNumber1"
    ComponentClass="SignalOffPageConnectorReferenceByNumber"
    ComponentClassURI="http://sandbox.dexpi.org/rdl/SignalOffPageConnectorReferenceByNumber" ...>
  ...
  <GenericAttributes Set="DexpiAttributes" ...>
    <GenericAttribute
      Name="ReferencedDrawingNumberAssignmentClass"
      AttributeURI="http://sandbox.dexpi.org/rdl/ReferencedDrawingNumberAssignmentClass"
      Format="string"
      Value="123/A93" />
    ...
  </GenericAttributes>
  ...
</SignalOffPageConnectorReference>