OperatedValve¶
Overview¶
Class
A valve that includes an external means of operation. (E.g. handwheel / lever / actuator.) (from http://data.posccaesar.org/rdl/RDS11141590).
Supertypes
Subtypes
Attributes (data)
Name |
Multiplicity |
Type |
---|---|---|
0..1 |
||
0..1 |
||
0..1 |
||
0..1 |
||
0..1 |
||
0..1 |
||
0..1 |
Implementation in Proteus Schema
The class is implemented as a Proteus XML element with RDL reference.
Tag: <PipingComponent>
RDL reference: OPERATED VALVE
ComponentClass: OperatedValve
ComponentClassURI: http://data.posccaesar.org/rdl/RDS11141590
Example
Implementation in Proteus Schema
<PipingComponent
ID="operatedValve1"
ComponentClass="OperatedValve"
ComponentClassURI="http://data.posccaesar.org/rdl/RDS11141590" ...>
...
</PipingComponent>
InsulationThickness¶
Attribute (data)
The insulation thickness of the OperatedValve.
Multiplicity: 0..1
Type: NullableLength
Implementation in Proteus Schema
The attribute is implemented as a DEXPI generic attribute for physical quantities.
RDL reference: INSULATION THICKNESS
Name: InsulationThickness
AttributeURI: http://data.posccaesar.org/rdl/RDS4238040
Example
The instance operatedValve1 represents an OperatedValve with an InsulationThickness of 40.0 mm.
Implementation in Proteus Schema
<PipingComponent
ID="operatedValve1"
ComponentClass="OperatedValve"
ComponentClassURI="http://data.posccaesar.org/rdl/RDS11141590" ...>
...
<GenericAttributes Set="DexpiAttributes" ...>
<GenericAttribute
Name="InsulationThickness"
AttributeURI="http://data.posccaesar.org/rdl/RDS4238040"
Format="double"
Value="40.0"
Units="Millimetre"
UnitsURI="http://data.posccaesar.org/rdl/RDS1357739" />
...
</GenericAttributes>
...
</PipingComponent>
InsulationType¶
Attribute (data)
The identification code for the insulation type related to the OperatedValve. So far, DEXPI does not define restrictions for valid values.
Multiplicity: 0..1
Type: NullableString
Implementation in Proteus Schema
The attribute is implemented as a DEXPI generic attribute for string values.
RDL reference: INSULATION TYPE ASSIGNMENT CLASS
Name: InsulationTypeAssignmentClass
Example
“Q” (String)
Implementation in Proteus Schema
<PipingComponent
ID="operatedValve1"
ComponentClass="OperatedValve"
ComponentClassURI="http://data.posccaesar.org/rdl/RDS11141590" ...>
...
<GenericAttributes Set="DexpiAttributes" ...>
<GenericAttribute
Name="InsulationTypeAssignmentClass"
AttributeURI="http://sandbox.dexpi.org/rdl/InsulationTypeAssignmentClass"
Format="string"
Value="Q" />
...
</GenericAttributes>
...
</PipingComponent>
NumberOfPorts¶
Attribute (data)
A specialization indicating the number of ports of the OperatedValve.
Multiplicity: 0..1
Implementation in Proteus Schema
The attribute is implemented as a DEXPI generic attribute for enumeration values.
RDL reference: NUMBER OF PORTS SPECIALIZATION
Name: NumberOfPortsSpecialization
AttributeURI: http://sandbox.dexpi.org/rdl/NumberOfPortsSpecialization
Example
2 port valve (NumberOfPortsClassification::TwoPortValve)
Implementation in Proteus Schema
<PipingComponent
ID="operatedValve1"
ComponentClass="OperatedValve"
ComponentClassURI="http://data.posccaesar.org/rdl/RDS11141590" ...>
...
<GenericAttributes Set="DexpiAttributes" ...>
<GenericAttribute
Name="NumberOfPortsSpecialization"
AttributeURI="http://sandbox.dexpi.org/rdl/NumberOfPortsSpecialization"
Format="anyURI"
Value="TwoPortValve"
ValueURI="http://data.posccaesar.org/rdl/RDS11506315" />
...
</GenericAttributes>
...
</PipingComponent>
Operation¶
Attribute (data)
A specialization indicating the operation of the OperatedValve.
Multiplicity: 0..1
Type: OperationClassification
Implementation in Proteus Schema
The attribute is implemented as a DEXPI generic attribute for enumeration values.
RDL reference: OPERATION SPECIALIZATION
Name: OperationSpecialization
AttributeURI: http://sandbox.dexpi.org/rdl/OperationSpecialization
Example
continuous operation (OperationClassification::ContinuousOperation)
Implementation in Proteus Schema
<PipingComponent
ID="operatedValve1"
ComponentClass="OperatedValve"
ComponentClassURI="http://data.posccaesar.org/rdl/RDS11141590" ...>
...
<GenericAttributes Set="DexpiAttributes" ...>
<GenericAttribute
Name="OperationSpecialization"
AttributeURI="http://sandbox.dexpi.org/rdl/OperationSpecialization"
Format="anyURI"
Value="ContinuousOperation"
ValueURI="http://data.posccaesar.org/rdl/RDS9710162" />
...
</GenericAttributes>
...
</PipingComponent>
PipingClassCode¶
Attribute (data)
The identification code of the piping class of the OperatedValve. So far, DEXPI does not define restrictions for valid values.
Multiplicity: 0..1
Type: NullableString
Implementation in Proteus Schema
The attribute is implemented as a DEXPI generic attribute for string values.
RDL reference: PIPING CLASS CODE ASSIGNMENT CLASS
Name: PipingClassCodeAssignmentClass
Example
“75HB13” (String)
Implementation in Proteus Schema
<PipingComponent
ID="operatedValve1"
ComponentClass="OperatedValve"
ComponentClassURI="http://data.posccaesar.org/rdl/RDS11141590" ...>
...
<GenericAttributes Set="DexpiAttributes" ...>
<GenericAttribute
Name="PipingClassCodeAssignmentClass"
AttributeURI="http://sandbox.dexpi.org/rdl/PipingClassCodeAssignmentClass"
Format="string"
Value="75HB13" />
...
</GenericAttributes>
...
</PipingComponent>
PipingComponentName¶
Attribute (data)
A string to classify the OperatedValve. DEXPI does not prescribe the classification system. Typically, company or site site standards are used.
Multiplicity: 0..1
Type: NullableString
Implementation in Proteus Schema
The attribute is implemented as a DEXPI generic attribute for string values.
RDL reference: PIPING COMPONENT NAME ASSIGNMENT CLASS
Name: PipingComponentNameAssignmentClass
Example
“73KH12” (String)
Implementation in Proteus Schema
<PipingComponent
ID="operatedValve1"
ComponentClass="OperatedValve"
ComponentClassURI="http://data.posccaesar.org/rdl/RDS11141590" ...>
...
<GenericAttributes Set="DexpiAttributes" ...>
<GenericAttribute
Name="PipingComponentNameAssignmentClass"
AttributeURI="http://sandbox.dexpi.org/rdl/PipingComponentNameAssignmentClass"
Format="string"
Value="73KH12" />
...
</GenericAttributes>
...
</PipingComponent>
PipingComponentNumber¶
Attribute (data)
An identifier of the OperatedValve. DEXPI does not prescribe the scope of the identifier, i.e., whether it should be unique in, e.g., a PipingNetworkSegment or a PipingNetworkSystem.
Multiplicity: 0..1
Type: NullableString
Implementation in Proteus Schema
The attribute is implemented as a DEXPI generic attribute for string values.
RDL reference: PIPING COMPONENT NUMBER ASSIGNMENT CLASS
Name: PipingComponentNumberAssignmentClass
Example
“C2” (String)
Implementation in Proteus Schema
<PipingComponent
ID="operatedValve1"
ComponentClass="OperatedValve"
ComponentClassURI="http://data.posccaesar.org/rdl/RDS11141590" ...>
...
<GenericAttributes Set="DexpiAttributes" ...>
<GenericAttribute
Name="PipingComponentNumberAssignmentClass"
AttributeURI="http://sandbox.dexpi.org/rdl/PipingComponentNumberAssignmentClass"
Format="string"
Value="C2" />
...
</GenericAttributes>
...
</PipingComponent>