FilteringCentrifuge

Plant::ProcessEquipment::FilteringCentrifuge

Overview

Concrete Class

RDL: FILTERING CENTRIFUGE (http://sandbox.dexpi.org/rdl/FilteringCentrifuge)

A centrifuge intended to separate solids from liquids by centrifugal process based on particle size.

(Fullscreen Diagram)

ConceptualObjectPlantAreaLocatedStructurePlantSystemLocatedStructurePlantTrainLocatedStructureTechnicalItemTechnicalItemParentStructureChamberOwnerNozzleOwnerProcessEquipmentTaggedPlantItemTransmissionDriverAttributeRepresentationRepresentationGroupNotePersistentIdentifierRolePlantModelPlantAreaPlantSystemPlantTrainCentrifugeChamberDryingChamberEquipmentVentFilteringCentrifugeMinimumParticleSize :Undefined | <PhysicalQuantity with UnitType → LengthUnit> [0..1]FilteringCentrifugeDrumMotorAsComponentMountNozzleSprayNozzleTransmissionSystemPerformedRoles**PersistentIdentifiers0..1*ReferencedNotes**Object*Represents*TaggedPlantItems0..1*PlantArea*0..1PlantSystem*0..1PlantTrain*0..1ParentStructure*0..1Chambers0..1*FilteringCentrifugeDrum0..10..1Nozzles0..1*DrivingTransmissionSystem0..10..1DryingChambers0..1*Motors0..1*Mounts0..1*SprayNozzles0..1*TransmissionSystems0..1*Vents0..1*

Supertypes

Members

Composition Properties

Name

Multiplicity

Type

Ordered

FilteringCentrifugeDrum

0..1

FilteringCentrifugeDrum

no

The filtering centrifuge drum of the FilteringCentrifuge.

Data Properties

Name

Multiplicity

Type

Ordered

Unique

MinimumParticleSize

0..1

Undefined | <PhysicalQuantity with UnitType → LengthUnit>

no

no

The minimum particle size of the FilteringCentrifuge.

FilteringCentrifugeDrum

Composition Property

The filtering centrifuge drum of the FilteringCentrifuge.

Type: FilteringCentrifugeDrum

Multiplicity: 0..1

Ordered: no

MinimumParticleSize

Data Property

The minimum particle size of the FilteringCentrifuge.

Type: Undefined | <PhysicalQuantity with UnitType → LengthUnit>

Multiplicity: 0..1

Ordered: no

Unique: no

RDL: MINIMUM PARTICLE SIZE (http://sandbox.dexpi.org/rdl/MinimumParticleSize)

Example

PhysicalQuantity(

     Unit = Micrometre,

     Value = 7.0)

Example in DEXPI XML

<Object type="Plant/ProcessEquipment.FilteringCentrifuge">
  <Data property="MinimumParticleSize">
    <AggregatedDataValue type="Core/PhysicalQuantities.PhysicalQuantity">
      <Data property="Unit">
        <DataReference data="Core/PhysicalQuantities.LengthUnit.Micrometre"/>
      </Data>
      <Data property="Value">
        <Double>7.0</Double>
      </Data>
    </AggregatedDataValue>
  </Data>
</Object>