HeatExchanger¶
Plant::ProcessEquipment::HeatExchanger
Overview¶
Concrete Class
RDL: HEAT EXCHANGER (http://data.posccaesar.org/rdl/RDS304199)
An apparatus or machine that has the capability of heat exchanging (from http://data.15926.org/rdl/RDS304199).
Supertypes
Subtypes
Members¶
Reference Properties¶
Name |
Multiplicity |
Type |
Ordered |
Unique |
Opposite Multiplicity |
|
|---|---|---|---|---|---|---|
0..1 |
no |
no |
0..1 |
The Agitator of the HeatExchanger, if applicable. |
Data Properties¶
Name |
Multiplicity |
Type |
Ordered |
Unique |
|
|---|---|---|---|---|---|
0..1 |
Undefined | <PhysicalQuantity with UnitType → PowerUnit> |
no |
no |
The heat flow rate for which the HeatExchanger is designed. |
|
0..1 |
Undefined | <PhysicalQuantity with UnitType → AreaUnit> |
no |
no |
The heat transfer area for which the HeatExchanger is designed. |
|
0..1 |
Undefined | <PhysicalQuantity with UnitType → HeatTransferCoefficientUnit> |
no |
no |
The heat transfer coefficient for which the HeatExchanger is designed. |
Agitator¶
Reference Property
The Agitator of the HeatExchanger, if applicable.
Type: Agitator
Multiplicity: 0..1
Ordered: no
Unique: no
Opposite Multiplicity: 0..1
DesignHeatFlowRate¶
Data Property
The heat flow rate for which the HeatExchanger is designed.
Type: Undefined | <PhysicalQuantity with UnitType → PowerUnit>
Multiplicity: 0..1
Ordered: no
Unique: no
RDL: DESIGN HEAT FLOW RATE (http://sandbox.dexpi.org/rdl/DesignHeatFlowRate)
Example¶
Value = 313.0)
DesignHeatTransferArea¶
Data Property
The heat transfer area for which the HeatExchanger is designed.
Type: Undefined | <PhysicalQuantity with UnitType → AreaUnit>
Multiplicity: 0..1
Ordered: no
Unique: no
RDL: DESIGN HEAT TRANSFER AREA (http://sandbox.dexpi.org/rdl/DesignHeatTransferArea)
Example¶
Unit = MetreSquared,
Value = 46.8)
DesignHeatTransferCoefficient¶
Data Property
The heat transfer coefficient for which the HeatExchanger is designed.
Type: Undefined | <PhysicalQuantity with UnitType → HeatTransferCoefficientUnit>
Multiplicity: 0..1
Ordered: no
Unique: no
RDL: DESIGN HEAT TRANSFER COEFFICIENT (http://sandbox.dexpi.org/rdl/DesignHeatTransferCoefficient)
Example¶
Unit = KilowattPerMetreSquaredKelvin,
Value = 1.2)
Example in DEXPI XML¶
<Object type="Plant/ProcessEquipment.HeatExchanger">
<Data property="DesignHeatFlowRate">
<AggregatedDataValue type="Core/PhysicalQuantities.PhysicalQuantity">
<Data property="Unit">
<DataReference data="Core/PhysicalQuantities.PowerUnit.Kilowatt"/>
</Data>
<Data property="Value">
<Double>313.0</Double>
</Data>
</AggregatedDataValue>
</Data>
<Data property="DesignHeatTransferArea">
<AggregatedDataValue type="Core/PhysicalQuantities.PhysicalQuantity">
<Data property="Unit">
<DataReference data="Core/PhysicalQuantities.AreaUnit.MetreSquared"/>
</Data>
<Data property="Value">
<Double>46.8</Double>
</Data>
</AggregatedDataValue>
</Data>
<Data property="DesignHeatTransferCoefficient">
<AggregatedDataValue type="Core/PhysicalQuantities.PhysicalQuantity">
<Data property="Unit">
<DataReference data="Core/PhysicalQuantities.HeatTransferCoefficientUnit.KilowattPerMetreSquaredKelvin"/>
</Data>
<Data property="Value">
<Double>1.2</Double>
</Data>
</AggregatedDataValue>
</Data>
</Object>