SafetyValveOrFitting¶
Plant::Piping::SafetyValveOrFitting
Overview¶
Concrete Class
RDL: SAFETY VALVE OR FITTING (http://sandbox.dexpi.org/rdl/SafetyValveOrFitting)
A safety valve or fitting.
Supertypes
Subtypes
Members¶
Data Properties¶
Name |
Multiplicity |
Type |
Ordered |
Unique |
|
|---|---|---|---|---|---|
0..1 |
no |
no |
The code of the piping class at the flow in side of SafetyValveOrFitting. |
||
0..1 |
no |
no |
The code of the piping class at the flow out side of SafetyValveOrFitting. |
||
0..1 |
no |
no |
The location registration number of the SafetyValveOrFitting. |
||
0..1 |
no |
no |
The position number of the SafetyValveOrFitting. |
||
0..1 |
Undefined | <PhysicalQuantity with UnitType → PressureGaugeUnit> |
no |
no |
The high pressure at which the SafetyValveOrFitting is activated. |
|
0..1 |
Undefined | <PhysicalQuantity with UnitType → PressureGaugeUnit> |
no |
no |
The low pressure at which the SafetyValveOrFitting is activated. |
FlowInPipingClassCode¶
Data Property
The code of the piping class at the flow in side of SafetyValveOrFitting.
Multiplicity: 0..1
Ordered: no
Unique: no
Example¶
"75HB13"
FlowOutPipingClassCode¶
Data Property
The code of the piping class at the flow out side of SafetyValveOrFitting.
Multiplicity: 0..1
Ordered: no
Unique: no
Example¶
"75HB13"
LocationRegistrationNumber¶
Data Property
The location registration number of the SafetyValveOrFitting.
Multiplicity: 0..1
Ordered: no
Unique: no
Example¶
"L-N123"
PositionNumber¶
Data Property
The position number of the SafetyValveOrFitting.
Multiplicity: 0..1
Ordered: no
Unique: no
RDL: POSITION NUMBER ASSIGNMENT CLASS (http://sandbox.dexpi.org/rdl/PositionNumberAssignmentClass)
Example¶
"SV 104.01"
SetPressureHigh¶
Data Property
The high pressure at which the SafetyValveOrFitting is activated.
Type: Undefined | <PhysicalQuantity with UnitType → PressureGaugeUnit>
Multiplicity: 0..1
Ordered: no
Unique: no
RDL: SET PRESSURE HIGH (http://sandbox.dexpi.org/rdl/SetPressureHigh)
Example¶
Value = 30.0)
SetPressureLow¶
Data Property
The low pressure at which the SafetyValveOrFitting is activated.
Type: Undefined | <PhysicalQuantity with UnitType → PressureGaugeUnit>
Multiplicity: 0..1
Ordered: no
Unique: no
RDL: SET PRESSURE LOW (http://sandbox.dexpi.org/rdl/SetPressureLow)
Example¶
Value = 0.0)
Example in DEXPI XML¶
<Object type="Plant/Piping.SafetyValveOrFitting">
<Data property="FlowInPipingClassCode">
<String>75HB13</String>
</Data>
<Data property="FlowOutPipingClassCode">
<String>75HB13</String>
</Data>
<Data property="LocationRegistrationNumber">
<String>L-N123</String>
</Data>
<Data property="PositionNumber">
<String>SV 104.01</String>
</Data>
<Data property="SetPressureHigh">
<AggregatedDataValue type="Core/PhysicalQuantities.PhysicalQuantity">
<Data property="Unit">
<DataReference data="Core/PhysicalQuantities.PressureGaugeUnit.Bar"/>
</Data>
<Data property="Value">
<Double>30.0</Double>
</Data>
</AggregatedDataValue>
</Data>
<Data property="SetPressureLow">
<AggregatedDataValue type="Core/PhysicalQuantities.PhysicalQuantity">
<Data property="Unit">
<DataReference data="Core/PhysicalQuantities.PressureGaugeUnit.Bar"/>
</Data>
<Data property="Value">
<Double>0.0</Double>
</Data>
</AggregatedDataValue>
</Data>
</Object>