CoolingTower

Plant::ProcessEquipment::CoolingTower

Overview

Concrete Class

RDL: COOLING TOWER (http://data.posccaesar.org/rdl/RDS14072341)

A cooler and an air cooled heat exchanger that is a tall structure through which air circulates by convection

(Fullscreen Diagram)

ConceptualObjectPlantAreaLocatedStructurePlantSystemLocatedStructurePlantTrainLocatedStructureTechnicalItemTechnicalItemParentStructureChamberOwnerNozzleOwnerProcessEquipmentTaggedPlantItemTransmissionDriverAttributeRepresentationRepresentationGroupNotePersistentIdentifierRolePlantModelPlantAreaPlantSystemPlantTrainChamberCoolingTowerDesignHeatFlowRate :Undefined | <PhysicalQuantity with UnitType → PowerUnit> [0..1]DesignVolumeFlowRate :Undefined | <PhysicalQuantity with UnitType → VolumeFlowRateUnit> [0..1]DryingChamberEquipmentVentMotorAsComponentMountNozzleSprayNozzleTransmissionSystemPerformedRoles**PersistentIdentifiers0..1*ReferencedNotes**Object*Represents*TaggedPlantItems0..1*PlantArea*0..1PlantSystem*0..1PlantTrain*0..1ParentStructure*0..1Chambers0..1*Nozzles0..1*DrivingTransmissionSystem0..10..1DryingChambers0..1*Motors0..1*Mounts0..1*SprayNozzles0..1*TransmissionSystems0..1*Vents0..1*

Supertypes

Subtypes

Members

Data Properties

Name

Multiplicity

Type

Ordered

Unique

DesignHeatFlowRate

0..1

Undefined | <PhysicalQuantity with UnitType → PowerUnit>

no

no

The heat flow rate for which the CoolingTower is designed.

DesignVolumeFlowRate

0..1

Undefined | <PhysicalQuantity with UnitType → VolumeFlowRateUnit>

no

no

The volume flow rate for which the CoolingTower is designed.

DesignHeatFlowRate

Data Property

The heat flow rate for which the CoolingTower is designed.

Type: Undefined | <PhysicalQuantity with UnitType → PowerUnit>

Multiplicity: 0..1

Ordered: no

Unique: no

RDL: DESIGN HEAT FLOW RATE (http://sandbox.dexpi.org/rdl/DesignHeatFlowRate)

Example

PhysicalQuantity(

     Unit = Kilowatt,

     Value = 313.0)

DesignVolumeFlowRate

Data Property

The volume flow rate for which the CoolingTower is designed.

Type: Undefined | <PhysicalQuantity with UnitType → VolumeFlowRateUnit>

Multiplicity: 0..1

Ordered: no

Unique: no

RDL: DESIGN VOLUME FLOW RATE (http://data.posccaesar.org/rdl/RDS14286227)

Example

PhysicalQuantity(

     Unit = MetreCubedPerHour,

     Value = 420.0)

Example in DEXPI XML

<Object type="Plant/ProcessEquipment.CoolingTower">
  <Data property="DesignHeatFlowRate">
    <AggregatedDataValue type="Core/PhysicalQuantities.PhysicalQuantity">
      <Data property="Unit">
        <DataReference data="Core/PhysicalQuantities.PowerUnit.Kilowatt"/>
      </Data>
      <Data property="Value">
        <Double>313.0</Double>
      </Data>
    </AggregatedDataValue>
  </Data>
  <Data property="DesignVolumeFlowRate">
    <AggregatedDataValue type="Core/PhysicalQuantities.PhysicalQuantity">
      <Data property="Unit">
        <DataReference data="Core/PhysicalQuantities.VolumeFlowRateUnit.MetreCubedPerHour"/>
      </Data>
      <Data property="Value">
        <Double>420.0</Double>
      </Data>
    </AggregatedDataValue>
  </Data>
</Object>