| Attribute |
Scope |
Type |
|
ConnectionNominalDiameterNumericalValueRepresentation
|
Public
|
Undefined | String
|
|
Notes:
|
A readable representation of the numerical value of the nominal<br/>diameter at the device connection of the OfflineMeasuringElement. The purpose of this<br/>value is to give a textual representation of the nominal diameter to be<br/>used in the graphics of a PID.<br/>
|
|
|
ConnectionNominalDiameterRepresentation
|
Public
|
Undefined | String
|
|
Notes:
|
A readable representation of the nominal diameter at the device<br/>connection of the OfflineMeasuringElement. The purpose of this value is to give a<br/>textual representation of the nominal diameter to be<br/>used in the graphics of a PID.<br/>
|
|
|
ConnectionNominalDiameterStandard
|
Public
|
NominalDiameterStandardClassification
|
|
Notes:
|
The nominal diameter of the device connection of the OfflineMeasuringElement, given as<br/>a reference to a nominal diameter standard and value.<br/>
|
|
|
ConnectionNominalDiameterTypeRepresentation
|
Public
|
Undefined | String
|
|
Notes:
|
A readable representation of the type of the nominal diameter at the<br/>device connection of the OfflineMeasuringElement. The purpose of this value is to give<br/>a textual representation of the nominal diameter to be used in the<br/>graphics of a PID.<br/>
|
|
|
FluidCode
|
Public
|
Undefined | String
|
|
Notes:
|
The identification code of the fluid related to the OfflineMeasuringElement. So<br/>far, DEXPI does not define restrictions for valid values.<br/>
|
|
|
HeatTracingType
|
Public
|
HeatTracingTypeClassification
|
|
Notes:
|
A specialization indicating the heat tracing type related to the<br/>OfflineMeasuringElement.<br/>
|
|
|
HeatTracingTypeRepresentation
|
Public
|
Undefined | String
|
|
Notes:
|
The heat tracing type related to the OfflineMeasuringElement, represented as a string.<br/>
|
|
|
InsulationThickness
|
Public
|
Undefined | (PhysicalQuantity with UnitType=LengthUnit)
|
|
Notes:
|
The insulation thickness of the OfflineMeasuringElement.<br/>
|
|
|
InsulationType
|
Public
|
Undefined | String
|
|
Notes:
|
The identification code for the insulation type related to the OfflineMeasuringElement. So far,<br/>DEXPI does not define restrictions for valid values.<br/>
|
|
|
LocationNominalDiameterNumericalValueRepresentation
|
Public
|
Undefined | String
|
|
Notes:
|
A readable representation of the numerical value of the nominal diameter<br/>at the location of the OfflineMeasuringElement. The purpose of this value is to give a<br/>textual representation of the nominal diameter to be used in the graphics<br/>of a PID.<br/>
|
|
|
LocationNominalDiameterRepresentation
|
Public
|
Undefined | String
|
|
Notes:
|
A readable representation of the nominal diameter at the location of the<br/>OfflineMeasuringElement. The purpose of this value is to give a textual representation<br/>of the nominal diameter to be used in the graphics of a PID.<br/>
|
|
|
LocationNominalDiameterStandard
|
Public
|
NominalDiameterStandardClassification
|
|
Notes:
|
The nominal diameter of the location of the OfflineMeasuringElement, given as a<br/>reference to a nominal diameter standard and value.<br/>
|
|
|
LocationNominalDiameterTypeRepresentation
|
Public
|
Undefined | String
|
|
Notes:
|
A readable representation of the type of the nominal diameter at the<br/>location of the OfflineMeasuringElement. The purpose of this value is to give a textual<br/>representation of the nominal diameter to be used in the graphics of a<br/>PID.<br/>
|
|
|
LowerLimitHeatTracingTemperature
|
Public
|
Undefined | (PhysicalQuantity with UnitType=TemperatureUnit)
|
|
Notes:
|
The lower limit for the temperature that a heat tracing system must<br/>ensure for the OfflineMeasuringElement.<br/>
|
|