DryCoolingTower

Overview

Class

A CoolingTower that is an indirect contact heat exchanger where, by full utilization of dry surface coil sections, no direct contact (and no evaporation) occurs between air and water; hence the water is cooled totally by sensible heat transfer (from http://data.15926.org/rdl/RDS14072386).

Supertypes

Attributes (data)

Name

Multiplicity

Type

DesignRotationalSpeed

0..1

NullableRotationalFrequency

DesignShaftPower

0..1

NullablePower

Attributes (composition)

Name

Multiplicity

Type

CoolingTowerRotor

0..1

CoolingTowerRotor

Implementation in Proteus Schema

The class is implemented as a Proteus XML element with RDL reference.

Tag: <Equipment>

RDL reference: DRY COOLING TOWER

ComponentClass: DryCoolingTower

Example

Implementation in Proteus Schema

<Equipment
    ID="dryCoolingTower1"
    ComponentClass="DryCoolingTower"
    ComponentClassURI="http://data.posccaesar.org/rdl/RDS14072386" ...>
  ...
</Equipment>

CoolingTowerRotor

Attribute (composition)

The cooling tower rotor of the DryCoolingTower.

Multiplicity: 0..1

Opposite multiplicity: 0..1

Implementation in Proteus Schema

The attribute is implemented using the XML hierarchy of the Proteus file: The element for the attribute value (a CoolingTowerRotor) is a child of the <Equipment> element for the attribute owner (a DryCoolingTower).

Example

Implementation in Proteus Schema

<Equipment
    ID="dryCoolingTower1"
    ComponentClass="DryCoolingTower"
    ComponentClassURI="http://data.posccaesar.org/rdl/RDS14072386" ...>
  ...
  <Equipment
      ID="coolingTowerRotor1"
      ComponentClass="CoolingTowerRotor"
      ComponentClassURI="http://sandbox.dexpi.org/rdl/CoolingTowerRotor" ...>
    ...
  <Equipment />
  ...
<Equipment />

DesignRotationalSpeed

Attribute (data)

The rotational speed for which the DryCoolingTower is designed.

Multiplicity: 0..1

Implementation in Proteus Schema

The attribute is implemented as a DEXPI generic attribute for physical quantities.

Name: DesignRotationalSpeed

Example

The instance dryCoolingTower1 represents a DryCoolingTower with a DesignRotationalSpeed of 180.0 min-1.

Implementation in Proteus Schema

<Equipment
    ID="dryCoolingTower1"
    ComponentClass="DryCoolingTower"
    ComponentClassURI="http://data.posccaesar.org/rdl/RDS14072386" ...>
  ...
  <GenericAttributes Set="DexpiAttributes" ...>
    <GenericAttribute
      Name="DesignRotationalSpeed"
      AttributeURI="http://sandbox.dexpi.org/rdl/DesignRotationalSpeed"
      Format="double"
      Value="180.0"
      Units="ReciprocalMinute"
      UnitsURI="http://data.posccaesar.org/rdl/RDS4316851589" />
    ...
  </GenericAttributes>
  ...
</Equipment>

DesignShaftPower

Attribute (data)

The shaft power for which the DryCoolingTower is designed.

Multiplicity: 0..1

Implementation in Proteus Schema

The attribute is implemented as a DEXPI generic attribute for physical quantities.

RDL reference: DESIGN SHAFT POWER

Name: DesignShaftPower

Example

The instance dryCoolingTower1 represents a DryCoolingTower with a DesignShaftPower of 400.0 kW.

Implementation in Proteus Schema

<Equipment
    ID="dryCoolingTower1"
    ComponentClass="DryCoolingTower"
    ComponentClassURI="http://data.posccaesar.org/rdl/RDS14072386" ...>
  ...
  <GenericAttributes Set="DexpiAttributes" ...>
    <GenericAttribute
      Name="DesignShaftPower"
      AttributeURI="http://sandbox.dexpi.org/rdl/DesignShaftPower"
      Format="double"
      Value="400.0"
      Units="Kilowatt"
      UnitsURI="http://data.posccaesar.org/rdl/RDS1330919" />
    ...
  </GenericAttributes>
  ...