Pump¶
Overview¶
Class
A machine that is capable of pumping but may require parts and subsystems for that capability.
Supertypes
Subtypes
Attributes (data)
Name |
Multiplicity |
Type |
---|---|---|
0..1 |
||
0..1 |
||
0..1 |
Implementation in Proteus Schema
The class is implemented as a Proteus XML element with RDL reference.
Tag: <Equipment>
RDL reference: PUMP
ComponentClass: Pump
ComponentClassURI: http://data.posccaesar.org/rdl/RDS327239
Example
Implementation in Proteus Schema
<Equipment
ID="pump1"
ComponentClass="Pump"
ComponentClassURI="http://data.posccaesar.org/rdl/RDS327239" ...>
...
</Equipment>
DesignPressureHead¶
Attribute (data)
The pressure head for which the Pump is designed.
Multiplicity: 0..1
Type: NullableLength
Implementation in Proteus Schema
The attribute is implemented as a DEXPI generic attribute for physical quantities.
RDL reference: DESIGN PRESSURE HEAD
Name: DesignPressureHead
AttributeURI: http://sandbox.dexpi.org/rdl/DesignPressureHead
Example
The instance pump1 represents a Pump with a DesignPressureHead of 40.0 m.
Implementation in Proteus Schema
<Equipment
ID="pump1"
ComponentClass="Pump"
ComponentClassURI="http://data.posccaesar.org/rdl/RDS327239" ...>
...
<GenericAttributes Set="DexpiAttributes" ...>
<GenericAttribute
Name="DesignPressureHead"
AttributeURI="http://sandbox.dexpi.org/rdl/DesignPressureHead"
Format="double"
Value="40.0"
Units="Metre"
UnitsURI="http://data.posccaesar.org/rdl/RDS1332674" />
...
</GenericAttributes>
...
</Equipment>
DesignVolumeFlowRate¶
Attribute (data)
The volume flow rate for which the Pump is designed.
Multiplicity: 0..1
Type: NullableVolumeFlowRate
Implementation in Proteus Schema
The attribute is implemented as a DEXPI generic attribute for physical quantities.
RDL reference: DESIGN VOLUME FLOW RATE
Name: DesignVolumeFlowRate
AttributeURI: http://data.posccaesar.org/rdl/RDS14286227
Example
The instance pump1 represents a Pump with a DesignVolumeFlowRate of 420.0 m3/h.
Implementation in Proteus Schema
<Equipment
ID="pump1"
ComponentClass="Pump"
ComponentClassURI="http://data.posccaesar.org/rdl/RDS327239" ...>
...
<GenericAttributes Set="DexpiAttributes" ...>
<GenericAttribute
Name="DesignVolumeFlowRate"
AttributeURI="http://data.posccaesar.org/rdl/RDS14286227"
Format="double"
Value="420.0"
Units="MetreCubedPerHour"
UnitsURI="http://data.posccaesar.org/rdl/RDS1321064" />
...
</GenericAttributes>
...
</Equipment>
DifferentialPressure¶
Attribute (data)
The differential pressure of the Pump.
Multiplicity: 0..1
Type: NullablePressureAbsolute
Implementation in Proteus Schema
The attribute is implemented as a DEXPI generic attribute for physical quantities.
RDL reference: DIFFERENTIAL PRESSURE
Name: DifferentialPressure
AttributeURI: http://data.posccaesar.org/rdl/RDS361574
Example
The instance pump1 represents a Pump with a DifferentialPressure of 4.8 bar.
Implementation in Proteus Schema
<Equipment
ID="pump1"
ComponentClass="Pump"
ComponentClassURI="http://data.posccaesar.org/rdl/RDS327239" ...>
...
<GenericAttributes Set="DexpiAttributes" ...>
<GenericAttribute
Name="DifferentialPressure"
AttributeURI="http://data.posccaesar.org/rdl/RDS361574"
Format="double"
Value="4.8"
Units="Bar"
UnitsURI="http://data.posccaesar.org/rdl/RDS1314539" />
...
</GenericAttributes>
...
</Equipment>