InlineMeasuringElement¶
Plant::Piping::InlineMeasuringElement
Overview¶
Concrete Class
RDL: INLINE MEASURING ELEMENT (http://sandbox.dexpi.org/rdl/InlineMeasuringElement)
An inline measuring element.
Supertypes
Subtypes
Members¶
Data Properties¶
Name |
Multiplicity |
Type |
Ordered |
Unique |
|
|---|---|---|---|---|---|
0..1 |
Undefined | <PhysicalQuantity with UnitType → LengthUnit> |
no |
no |
The insulation thickness of the InlineMeasuringElement. |
|
0..1 |
no |
no |
The identification code for the insulation type related to the InlineMeasuringElement. So far, DEXPI does not define restrictions for valid values. |
||
0..1 |
no |
no |
A string to classify the InlineMeasuringElement. DEXPI does not prescribe the classification system. Typically, company or site site standards are used. |
||
0..1 |
no |
no |
An identifier of the InlineMeasuringElement. DEXPI does not prescribe the scope of the identifier, i.e., whether it should be unique in, e.g., a PipingNetworkSegment or a PipingNetworkSystem. |
InsulationThickness¶
Data Property
The insulation thickness of the InlineMeasuringElement.
Type: Undefined | <PhysicalQuantity with UnitType → LengthUnit>
Multiplicity: 0..1
Ordered: no
Unique: no
RDL: INSULATION THICKNESS (http://data.posccaesar.org/rdl/RDS4238040)
Example¶
Unit = Millimetre,
Value = 40.0)
InsulationType¶
Data Property
The identification code for the insulation type related to the InlineMeasuringElement. So far, DEXPI does not define restrictions for valid values.
Multiplicity: 0..1
Ordered: no
Unique: no
RDL: INSULATION TYPE ASSIGNMENT CLASS (http://sandbox.dexpi.org/rdl/InsulationTypeAssignmentClass)
Example¶
"Q"
PipingComponentName¶
Data Property
A string to classify the InlineMeasuringElement. DEXPI does not prescribe the classification system. Typically, company or site site standards are used.
Multiplicity: 0..1
Ordered: no
Unique: no
Example¶
"73KH12"
PipingComponentNumber¶
Data Property
An identifier of the InlineMeasuringElement. DEXPI does not prescribe the scope of the identifier, i.e., whether it should be unique in, e.g., a PipingNetworkSegment or a PipingNetworkSystem.
Multiplicity: 0..1
Ordered: no
Unique: no
Example¶
"C2"
Example in DEXPI XML¶
<Object type="Plant/Piping.InlineMeasuringElement">
<Data property="InsulationThickness">
<AggregatedDataValue type="Core/PhysicalQuantities.PhysicalQuantity">
<Data property="Unit">
<DataReference data="Core/PhysicalQuantities.LengthUnit.Millimetre"/>
</Data>
<Data property="Value">
<Double>40.0</Double>
</Data>
</AggregatedDataValue>
</Data>
<Data property="InsulationType">
<String>Q</String>
</Data>
<Data property="PipingComponentName">
<String>73KH12</String>
</Data>
<Data property="PipingComponentNumber">
<String>C2</String>
</Data>
</Object>