PipingComponent

Plant::Piping::PipingComponent

Overview

Abstract Class

A piping component

(Fullscreen Diagram)

ConceptualObjectSensingLocationPipingComponentFluidCode :Undefined | String [0..1]HeatTracingType :HeatTracingTypeClassification [0..1]HeatTracingTypeRepresentation :Undefined | String [0..1]LowerLimitHeatTracingTemperature :Undefined | <PhysicalQuantity with UnitType → TemperatureUnit> [0..1]OnHold :OnHoldClassification [0..1]PipingClassArtefact :PipingClassArtefactClassification [0..1]PressureTestCircuitNumber :Undefined | String [0..1]PipingNetworkSegmentItemPipingNodeOwnerPipingSourceItemPipingTargetItemAttributeRepresentationRepresentationGroupNotePersistentIdentifierRolePipingNodePerformedRoles**PersistentIdentifiers0..1*ReferencedNotes**Object*Represents*Nodes0..1*

Supertypes

Subtypes

Members

Data Properties

Name

Multiplicity

Type

Ordered

Unique

FluidCode

0..1

Undefined | String

no

no

The identification code of the fluid related to the PipingComponent. So far, DEXPI does not define restrictions for valid values.

HeatTracingType

0..1

HeatTracingTypeClassification

no

no

A specialization indicating the heat tracing type related to the PipingComponent.

HeatTracingTypeRepresentation

0..1

Undefined | String

no

no

The heat tracing type related to the PipingComponent, represented as a string.

LowerLimitHeatTracingTemperature

0..1

Undefined | <PhysicalQuantity with UnitType → TemperatureUnit>

no

no

The lower limit for the temperature that a heat tracing system must ensure for the PipingComponent.

OnHold

0..1

OnHoldClassification

no

no

A specialization indicating if the PipingComponent is on hold or not.

PipingClassArtefact

0..1

PipingClassArtefactClassification

no

no

A specialization indicating if the PipingComponent is an artefact that is described by a piping class.

PressureTestCircuitNumber

0..1

Undefined | String

no

no

The number of the pressure test circuit of the PipingComponent.

FluidCode

Data Property

The identification code of the fluid related to the PipingComponent. So far, DEXPI does not define restrictions for valid values.

Type: Undefined | String

Multiplicity: 0..1

Ordered: no

Unique: no

RDL: FLUID CODE ASSIGNMENT CLASS (http://sandbox.dexpi.org/rdl/FluidCodeAssignmentClass)

Example

"MNb"

HeatTracingType

Data Property

A specialization indicating the heat tracing type related to the PipingComponent.

Type: HeatTracingTypeClassification

Multiplicity: 0..1

Ordered: no

Unique: no

RDL: HEAT TRACING TYPE SPECIALIZATION (http://sandbox.dexpi.org/rdl/HeatTracingTypeSpecialization)

Example

ElectricalHeatTracingSystem

HeatTracingTypeRepresentation

Data Property

The heat tracing type related to the PipingComponent, represented as a string.

Type: Undefined | String

Multiplicity: 0..1

Ordered: no

Unique: no

RDL: HEAT TRACING TYPE REPRESENTATION ASSIGNMENT CLASS (http://sandbox.dexpi.org/rdl/HeatTracingTypeRepresentationAssignmentClass)

Example

"E"

LowerLimitHeatTracingTemperature

Data Property

The lower limit for the temperature that a heat tracing system must ensure for the PipingComponent.

Type: Undefined | <PhysicalQuantity with UnitType → TemperatureUnit>

Multiplicity: 0..1

Ordered: no

Unique: no

RDL: LOWER LIMIT HEAT TRACING TEMPERATURE (http://sandbox.dexpi.org/rdl/LowerLimitHeatTracingTemperature)

Example

PhysicalQuantity(

     Unit = DegreeCelsius,

     Value = 100.0)

OnHold

Data Property

A specialization indicating if the PipingComponent is on hold or not.

Type: OnHoldClassification

Multiplicity: 0..1

Ordered: no

Unique: no

RDL: ON HOLD SPECIALIZATION (http://sandbox.dexpi.org/rdl/OnHoldSpecialization)

Example

OnHold

PipingClassArtefact

Data Property

A specialization indicating if the PipingComponent is an artefact that is described by a piping class.

Type: PipingClassArtefactClassification

Multiplicity: 0..1

Ordered: no

Unique: no

RDL: PIPING CLASS ARTEFACT SPECIALIZATION (http://sandbox.dexpi.org/rdl/PipingClassArtefactSpecialization)

Example

PipingClassArtefact

PressureTestCircuitNumber

Data Property

The number of the pressure test circuit of the PipingComponent.

Type: Undefined | String

Multiplicity: 0..1

Ordered: no

Unique: no

RDL: PRESSURE TEST CIRCUIT NUMBER ASSIGNMENT CLASS (http://sandbox.dexpi.org/rdl/PressureTestCircuitNumberAssignmentClass)

Example

"TC123"