EjectorPump¶
Plant::ProcessEquipment::EjectorPump
Overview¶
Concrete Class
RDL: EJECTOR PUMP (http://data.posccaesar.org/rdl/RDS860624)
A pump which uses pressurized gas or liquid passing through an ejector to transport liquid (from http://data.posccaesar.org/rdl/RDS860624).
Supertypes
Members¶
Data Properties¶
Name |
Multiplicity |
Type |
Ordered |
Unique |
|
|---|---|---|---|---|---|
0..1 |
Undefined | <PhysicalQuantity with UnitType → VolumeFlowRateUnit> |
no |
no |
The capacity of the volume flow rate for the motive fluid for which the EjectorPump is designed. |
DesignCapacityMotiveFluid¶
Data Property
The capacity of the volume flow rate for the motive fluid for which the EjectorPump is designed.
Type: Undefined | <PhysicalQuantity with UnitType → VolumeFlowRateUnit>
Multiplicity: 0..1
Ordered: no
Unique: no
RDL: DESIGN CAPACITY MOTIVE FLUID (http://sandbox.dexpi.org/rdl/DesignCapacityMotiveFluid)
Example¶
Value = 40.0)
Example in DEXPI XML¶
<Object type="Plant/ProcessEquipment.EjectorPump">
<Data property="DesignCapacityMotiveFluid">
<AggregatedDataValue type="Core/PhysicalQuantities.PhysicalQuantity">
<Data property="Unit">
<DataReference data="Core/PhysicalQuantities.VolumeFlowRateUnit.MetreCubedPerHour"/>
</Data>
<Data property="Value">
<Double>40.0</Double>
</Data>
</AggregatedDataValue>
</Data>
</Object>