Pump

Plant::ProcessEquipment::Pump

Overview

Concrete Class

RDL: PUMP (http://data.posccaesar.org/rdl/RDS327239)

A machine that is capable of pumping but may require parts and subsystems for that capability.

(Fullscreen Diagram)

ConceptualObjectPlantAreaLocatedStructurePlantSystemLocatedStructurePlantTrainLocatedStructureTechnicalItemTechnicalItemParentStructureChamberOwnerNozzleOwnerProcessEquipmentTaggedPlantItemTransmissionDriverAttributeRepresentationRepresentationGroupNotePersistentIdentifierRolePlantModelPlantAreaPlantSystemPlantTrainChamberDryingChamberEquipmentVentMotorAsComponentMountNozzlePumpDesignPressureHead :Undefined | <PhysicalQuantity with UnitType → LengthUnit> [0..1]DesignVolumeFlowRate :Undefined | <PhysicalQuantity with UnitType → VolumeFlowRateUnit> [0..1]DifferentialPressure :Undefined | <PhysicalQuantity with UnitType → PressureAbsoluteUnit> [0..1]SprayNozzleTransmissionSystemPerformedRoles**PersistentIdentifiers0..1*ReferencedNotes**Object*Represents*TaggedPlantItems0..1*PlantArea*0..1PlantSystem*0..1PlantTrain*0..1ParentStructure*0..1Chambers0..1*Nozzles0..1*DrivingTransmissionSystem0..10..1DryingChambers0..1*Motors0..1*Mounts0..1*SprayNozzles0..1*TransmissionSystems0..1*Vents0..1*

Supertypes

Subtypes

Members

Data Properties

Name

Multiplicity

Type

Ordered

Unique

DesignPressureHead

0..1

Undefined | <PhysicalQuantity with UnitType → LengthUnit>

no

no

The pressure head for which the Pump is designed.

DesignVolumeFlowRate

0..1

Undefined | <PhysicalQuantity with UnitType → VolumeFlowRateUnit>

no

no

The volume flow rate for which the Pump is designed.

DifferentialPressure

0..1

Undefined | <PhysicalQuantity with UnitType → PressureAbsoluteUnit>

no

no

The differential pressure of the Pump.

DesignPressureHead

Data Property

The pressure head for which the Pump is designed.

Type: Undefined | <PhysicalQuantity with UnitType → LengthUnit>

Multiplicity: 0..1

Ordered: no

Unique: no

RDL: DESIGN PRESSURE HEAD (http://sandbox.dexpi.org/rdl/DesignPressureHead)

Example

PhysicalQuantity(

     Unit = Metre,

     Value = 40.0)

DesignVolumeFlowRate

Data Property

The volume flow rate for which the Pump is designed.

Type: Undefined | <PhysicalQuantity with UnitType → VolumeFlowRateUnit>

Multiplicity: 0..1

Ordered: no

Unique: no

RDL: DESIGN VOLUME FLOW RATE (http://data.posccaesar.org/rdl/RDS14286227)

Example

PhysicalQuantity(

     Unit = MetreCubedPerHour,

     Value = 420.0)

DifferentialPressure

Data Property

The differential pressure of the Pump.

Type: Undefined | <PhysicalQuantity with UnitType → PressureAbsoluteUnit>

Multiplicity: 0..1

Ordered: no

Unique: no

RDL: DIFFERENTIAL PRESSURE (http://data.posccaesar.org/rdl/RDS361574)

Example

PhysicalQuantity(

     Unit = Bar,

     Value = 4.8)

Example in DEXPI XML

<Object type="Plant/ProcessEquipment.Pump">
  <Data property="DesignPressureHead">
    <AggregatedDataValue type="Core/PhysicalQuantities.PhysicalQuantity">
      <Data property="Unit">
        <DataReference data="Core/PhysicalQuantities.LengthUnit.Metre"/>
      </Data>
      <Data property="Value">
        <Double>40.0</Double>
      </Data>
    </AggregatedDataValue>
  </Data>
  <Data property="DesignVolumeFlowRate">
    <AggregatedDataValue type="Core/PhysicalQuantities.PhysicalQuantity">
      <Data property="Unit">
        <DataReference data="Core/PhysicalQuantities.VolumeFlowRateUnit.MetreCubedPerHour"/>
      </Data>
      <Data property="Value">
        <Double>420.0</Double>
      </Data>
    </AggregatedDataValue>
  </Data>
  <Data property="DifferentialPressure">
    <AggregatedDataValue type="Core/PhysicalQuantities.PhysicalQuantity">
      <Data property="Unit">
        <DataReference data="Core/PhysicalQuantities.PressureAbsoluteUnit.Bar"/>
      </Data>
      <Data property="Value">
        <Double>4.8</Double>
      </Data>
    </AggregatedDataValue>
  </Data>
</Object>